HISTORY LOG 1 ;SYS 0 c1992 YORK INTERNATIONAL CORP. VERSION C.03F.00 TODAY IS MON 7:32PM 07/25/16 CHILLED LEAVING= 45.0~F; RETURN= 56.6~F EVAP = 61.0 PSIG; COND = 98.8 PSIG OIL PRESSURE = 46.4 PSID NO OPTIONS INSTALLED SOLID STATE STARTER NOT INSTALLED COND LEAVING = 93.7~F; RETURN = 84.7~F MOTOR CURRENT = 17 %FLA OPER. HOURS =44486; START COUNTER = 2032 LEAVING SETPOINT = 43.0~F CURRENT LIMIT= 95% FLA SETPOINT=240MIN @ 99%FLA, 0 MIN LEFT S M T W T F S HOLIDAY NOTED BY * REMOTE TEMP SETPOINT RANGE = 20~F SAT TEMPS EVAP = 62.7~F, COND= 86.9~F DISCHARGE TEMP=109.3~F,OIL TEMP=139.9~F HOP = 102.1 PSIG; LOP = 57.1 PSIG SUN START = 12:00AM, STOP = 12:00AM MON START = 12:00AM, STOP = 12:00AM TUE START = 12:00AM, STOP = 12:00AM WED START = 12:00AM, STOP = 12:00AM THU START = 12:00AM, STOP = 12:00AM FRI START = 12:00AM, STOP = 12:00AM SAT START = 12:00AM, STOP = 12:00AM HOL START = 12:00AM, STOP = 12:00AM COMP MOTOR STARTER - ON PRV CLOSE - OFF REMOTE MODE READY TO START RELAY - ON VENT LINE VALVE - ON RETURN OIL SOLENOID VALVE - ON OIL PUMP - ON CHILLED WATER PUMP - ON OKI AUTO PRINT INTERVAL = NOT PROGRAMMED SYSTEM RUN - LEAVING TEMP CONTROL SAFETY SHUTDOWN RELAY - ON CYCLING SHUTDOWN RELAY - OFF MON 10:12PM PWR FAULT-CALL YORK SERVICE  HISTORY LOG 2 ;SYS 0 c1992 YORK INTERNATIONAL CORP. VERSION C.03F.00 TODAY IS MON 7:32PM 07/25/16 CHILLED LEAVING= 45.0~F; RETURN= 56.6~F EVAP = 61.0 PSIG; COND = 98.8 PSIG OIL PRESSURE = 46.4 PSID NO OPTIONS INSTALLED SOLID STATE STARTER NOT INSTALLED COND LEAVING = 93.7~F; RETURN = 84.7~F MOTOR CURRENT = 17 %FLA OPER. HOURS =44486; START COUNTER = 2032 LEAVING SETPOINT = 43.0~F CURRENT LIMIT= 95% FLA SETPOINT=240MIN @ 99%FLA, 0 MIN LEFT S M T W T F S HOLIDAY NOTED BY * REMOTE TEMP SETPOINT RANGE = 20~F SAT TEMPS EVAP = 62.7~F, COND= 86.9~F DISCHARGE TEMP=109.3~F,OIL TEMP=139.9~F HOP = 102.1 PSIG; LOP = 57.1 PSIG SUN START = 12:00AM, STOP = 12:00AM MON START = 12:00AM, STOP = 12:00AM TUE START = 12:00AM, STOP = 12:00AM WED START = 12:00AM, STOP = 12:00AM THU START = 12:00AM, STOP = 12:00AM FRI START = 12:00AM, STOP = 12:00AM SAT START = 12:00AM, STOP = 12:00AM HOL START = 12:00AM, STOP = 12:00AM COMP MOTOR STARTER - ON PRV CLOSE - OFF REMOTE MODE READY TO START RELAY - ON VENT LINE VALVE - ON RETURN OIL SOLENOID VALVE - ON OIL PUMP - ON CHILLED WATER PUMP - ON OKI AUTO PRINT INTERVAL = NOT PROGRAMMED SYSTEM RUN - LEAVING TEMP CONTROL SAFETY SHUTDOWN RELAY - ON CYCLING SHUTDOWN RELAY - OFF MON 7:32PM PWR FAULT-CALL YORK SERVICE  HISTORY LOG 3 ;SYS 0 c1992 YORK INTERNATIONAL CORP. VERSION C.03F.00 TODAY IS WED 2:24AM 08/12/15 CHILLED LEAVING= 40.4~F; RETURN= 51.7~F EVAP = 28.3 PSIG; COND = 100.3 PSIG OIL PRESSURE = 42.1 PSID NO OPTIONS INSTALLED SOLID STATE STARTER NOT INSTALLED COND LEAVING = 83.3~F; RETURN = 74.2~F MOTOR CURRENT = 79 %FLA OPER. HOURS =43126; START COUNTER = 1953 LEAVING SETPOINT = 44.0~F CURRENT LIMIT= 95% FLA SETPOINT=240MIN @ 99%FLA, 0 MIN LEFT S M T W T F S HOLIDAY NOTED BY * REMOTE TEMP SETPOINT RANGE = 20~F SAT TEMPS EVAP = 32.5~F, COND= 87.7~F DISCHARGE TEMP=110.7~F,OIL TEMP=135.0~F HOP = 69.2 PSIG; LOP = 27.8 PSIG SUN START = 12:00AM, STOP = 12:00AM MON START = 12:00AM, STOP = 12:00AM TUE START = 12:00AM, STOP = 12:00AM WED START = 12:00AM, STOP = 12:00AM THU START = 12:00AM, STOP = 12:00AM FRI START = 12:00AM, STOP = 12:00AM SAT START = 12:00AM, STOP = 12:00AM HOL START = 12:00AM, STOP = 12:00AM COMP MOTOR STARTER - ON PRV CLOSE - OFF REMOTE MODE READY TO START RELAY - ON VENT LINE VALVE - ON RETURN OIL SOLENOID VALVE - ON OIL PUMP - ON CHILLED WATER PUMP - ON OKI AUTO PRINT INTERVAL = NOT PROGRAMMED SYSTEM RUN - LEAVING TEMP CONTROL SAFETY SHUTDOWN RELAY - OFF CYCLING SHUTDOWN RELAY - ON SUN 11:03PM SYSTEM CYCLING-AUTOSTART  HISTORY LOG 4 ;SYS 0 c1992 YORK INTERNATIONAL CORP. VERSION C.03F.00 TODAY IS THU 8:08PM 07/09/15 CHILLED LEAVING= 45.0~F; RETURN= 55.8~F EVAP = 50.2 PSIG; COND = 96.3 PSIG OIL PRESSURE = 45.7 PSID NO OPTIONS INSTALLED SOLID STATE STARTER NOT INSTALLED COND LEAVING = 91.7~F; RETURN = 83.6~F MOTOR CURRENT = 52 %FLA OPER. HOURS =42571; START COUNTER = 1936 LEAVING SETPOINT = 43.0~F CURRENT LIMIT= 95% FLA SETPOINT=240MIN @ 99%FLA, 0 MIN LEFT S M T W T F S HOLIDAY NOTED BY * REMOTE TEMP SETPOINT RANGE = 20~F SAT TEMPS EVAP = 54.0~F, COND= 85.5~F DISCHARGE TEMP=119.1~F,OIL TEMP=139.5~F HOP = 87.9 PSIG; LOP = 42.8 PSIG SUN START = 12:00AM, STOP = 12:00AM MON START = 12:00AM, STOP = 12:00AM TUE START = 12:00AM, STOP = 12:00AM WED START = 12:00AM, STOP = 12:00AM THU START = 12:00AM, STOP = 12:00AM FRI START = 12:00AM, STOP = 12:00AM SAT START = 12:00AM, STOP = 12:00AM HOL START = 12:00AM, STOP = 12:00AM COMP MOTOR STARTER - ON PRV CLOSE - OFF REMOTE MODE READY TO START RELAY - ON VENT LINE VALVE - ON RETURN OIL SOLENOID VALVE - ON OIL PUMP - ON CHILLED WATER PUMP - ON OKI AUTO PRINT INTERVAL = NOT PROGRAMMED SYSTEM RUN - CURRENT LIMIT IN EFFECT SAFETY SHUTDOWN RELAY - OFF CYCLING SHUTDOWN RELAY - ON THU 8:08PM FLOW SWITCH-AUTOSTART